KEN Sheng-ye, DUAN Qin, SU Dan-dan, YANG Yi, TIAN Fei-yu, YANG Xue-yan. Determination of Nicotine in Tobacco Concrete by Gas Chromatography[J]. Analysis and Testing Technology and Instruments, 2022, 28(2): 205-209. DOI: 10.16495/j.1006-3757.2022.02.015
Citation: KEN Sheng-ye, DUAN Qin, SU Dan-dan, YANG Yi, TIAN Fei-yu, YANG Xue-yan. Determination of Nicotine in Tobacco Concrete by Gas Chromatography[J]. Analysis and Testing Technology and Instruments, 2022, 28(2): 205-209. DOI: 10.16495/j.1006-3757.2022.02.015

Determination of Nicotine in Tobacco Concrete by Gas Chromatography

  • A gas chromatography-flame ionization (GC-FID) method has been developed for the determination of nicotine in the tobacco concrete using 2-methylquinoline as the internal standards, five tobacco concrete samples were determined. The results showed that the limit of detection and limit of quantitation were 0.27 mg/g and 0.89 mg/g, respectively. The recoveries were 95.00%~98.58%. The contents of nicotine in the samples ranged from 19.66~54.97 mg/g. The method is easy, sensitive and accurate, and is suitable for the determination of nicotine in the tobacco concrete.