Determination of the NS-3 Corrosion Inhibitor Content in Decalcifying Process Drainage System by High Performance Liquid Chromatography
-
Graphical Abstract
-
Abstract
A Reversed-Phase High Performance Liquid Chromatographic method was established for rapid determination of the content of NS-3 corrosion inhibitor in the electric desalting and decalcifying process.The results were analyzed on an RP-18 column using acetonitrile-CH2Cl2=9:1((V/V)) as the mobile phase and UV-detected at 300 nm.The results show that in the range of 100~900 mg/kg,the area and the content is in a well linear correlation(r=0.9999,RSD and RD%2.0%(n=8)).Using CH2Cl2 as the extractant agent,the average recovery is 100%±2%,and the detection limit is 0.75 mg/kg.At the same time,this method also has the simple,rapid,well repeat,etc.advantages.
-
-