MEN Sheng-hui. Uncertainty Evaluation of Measurement of Carbon, Silicon, Manganese, Phosphorus, Sulfur Content in HO8A Eire Rod by Spark Discharge Atomic Emission Spectrometry[J]. Analysis and Testing Technology and Instruments, 2013, 19(4): 238-243.
Citation: MEN Sheng-hui. Uncertainty Evaluation of Measurement of Carbon, Silicon, Manganese, Phosphorus, Sulfur Content in HO8A Eire Rod by Spark Discharge Atomic Emission Spectrometry[J]. Analysis and Testing Technology and Instruments, 2013, 19(4): 238-243.

Uncertainty Evaluation of Measurement of Carbon, Silicon, Manganese, Phosphorus, Sulfur Content in HO8A Eire Rod by Spark Discharge Atomic Emission Spectrometry

  • Wire samples using special fixtures,and self-made rod of internal control samples were used to achieve analyze the H08A sample rod of 6.5 mm diameter, adopting a continuous excited mode by the spark discharge atomic emission spectrometry. The uncertainty factors of the method were discussed. And uncertainty evaluation of C,Si,Mn,P and S in the HO8A wire rod electrode samples were carried out, the analytical results of uncertainty met the production testing requirements. The method is suitable for the production on-line testing.